.

300 500V XLPE Insulated, PVC Sheathed Power Cables (Single Core)

300/500V XLPE Insulated,Website:, PVC Sheathed Power Cables (Single Core)Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design to IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING300/500VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C for XLPE250°C in short-circuit for 5secs max.Minimum bending radius: 6 x Overall Diameter (unarmoured cable)10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Overall DiameterNominal Overall DiameterNoxmm2No./mmmmmmkg/km1x1.57/0.530.503.8271x2.57/0.670.504.2371x4.07/0.850.504.854Electrical PropertiesConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1..


Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

PE Insulated, LSZH Sheathed And Overall Screened, Armoured Instrumentation Cables (Single Pair)
PE Insulated, LSZH Sheathed And Overall Screened, Armoured Instrumentation Cables (Single Pair) PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBasic des...
0.6/1 KV HEPR Insulated, LSOH (SHF1) Sheathed Flame Retardant Power Control Cables (Multicore)
0.6/1 KV HEPR Insulated, LSOH (SHF1) Sheathed Flame Retardant Power Control Cables (Multicore) 0.6/1 kV HEPR Insulated,Website:, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Multicore)ApplicationThese cables are used for fixed...
Belden9836
Belden9836 Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9836ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s...
Flame Retardant CAT5e Data Cables PVC Sheath
Flame Retardant CAT5e Data Cables PVC Sheath Flame Retardant CAT5e Data CablesCAT5e U/UTP4P24CAT5e F/UTP4P24CAT5e SF/UTP4P24Application:Cat5E is a cable standard for Gigabit Ethernet and other...
RG59 Armoured NEK606 Coaxial Cable
RG59 Armoured NEK606 Coaxial Cable 75Ω RG59 Armoured Coaxial Cable NEK606Applications :These 75Ω coaxial cables are suitable for installation on board of ships and other indoor mari...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes