Fire Resistant Central Loose Tube Optical Fiber Cables
Fire Resistant Central Loose Tube Optical Fiber CablesApplicationThese optical fiber cables are designed to data transmission in ship and specially in cruise ship where low smoke,Website:, halogen free and fire resistant cables are required to increase safety on board, suitable for flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants.StandardsIEC 60092-350/351/352/353/359/370/376IEC 60332-1-2IEC 60332-3-22IEC 60754-1/2IEC 61034IEC 60331-11 and -25ConstructionOptical FiberLoose tube, gel filled.Inner TapeFire protection tape.Outer TapeFire protection tape.Outer SheathSHF1.Fiber SpecificationG50/125G62.5/125E9/125Geometry/Mechanical PropertiesCore Diameterμm50 μ 2.562.5 μ 3Mode Field Diameter (at 1310 nm)μm9.2 μ 0.4Cladding Diameterµm125 μ 2125 μ 1125 μ 2Coating Diameterµm245 μ 10245 μ 5245 μ 10Core Non-circularity%< 5< 5Cladding Non-circularity%< 1< 1< 1Core/Clad Concentricity Errorµm< 1.5< 1.5< 0.8Eccentricity of Coatingµm< 10< 10< 10Screen Test≥100 kpsi≥100 kpsi≥100 kpsiTransmission PropertiesOM2OM1OS1WavelengthnmAttenuation Max.dB/km2.70.83.20.90.360.22Bandwidth Min.MHz. kmEffective Group of Refraction1.4831.4781.4971.4931.46951.4701Numerical Aperture0.200 μ 0.0150.275 μ 0.015Dispersion Coefficient Max.ps/nm.km3.518Zero Dispersion Wavelengthnm1300–1322Dispersion Slopeps/nm² .km≤0.092Cutoff Wavelength (cabled)nm≤1250Polarization Mode Dispersionps/km1/2≤0.1Mechanical and Thermal PropertiesBending Radius for Fixed Installations: 20×ODTemperature Range: -20℃ ~ +60℃Dimensions and WeightPart No.No. of Optical FibersNominal Overall Diameter mmNominal Weight kg/kmUE092-FCLA-X-12-H-J1210.0115UE092-FCLB-X-24-H-J2410.5125Note: X: Fiber type (0=Fiber and copper conductors in cable 4=50/125 multi-mode fiber (OM3); 5=50/125 multi-mode fiber (OM2); 6=50/125 multi-mode fiber (OM1); 7=NZDS SM fiber per G.656.; 8=NZDS SM fiber per G.655.; 9=Standard SM fiber per G.652.D)
Other supplier products
|
|
S15 BFOU-HCF(i) 250 V Fire Resistant Instrument cable NEK 606Applications :These cables are fire resistant,Website:, flame retardant, low smoke and... |
|
|
300V Mica+LSZH Insulated & LSZH Sheathed Fire Alarm CablesJE-H(St)H…Bd FE180 E90. (CU/MICA+LSZH/OS/LSZH 300V Class 1 )JE-H(St)H…Bd FE180 E90 BMK* (... |
|
|
Multipair Individually Screened Cables-Belden Equivalent 9733ApplicationsThese cables have individually screened pairs laid up. Each individually s... |
|
|
UL Industrial Cables RHH or RHW-2 or USE-2,Website:, 600V, EPR / CSPApplication and DescriptionThese cables are designed for use in lighting and po... |
|
|
Harmonized Code Industrial Cables H05V3V3H6-F/ H05V3V3D3H6-FApplication and DescriptionThis kind of flat cables are used in crews of elevators for ... |
供应产品
Same products