N2XCY
German Standard Industrial Cables N2XCYApplication and DescriptionIn indoor installation,Website:, in cable ducts outdoor and underground for power station, industrial plants and switching as well as local supply systems. Used for indoor installations for wiring of apparatus panels and switch board. Not to be used outdoors or in wet surroundings.Standard and ApprovalIEC 60502 -1, VDE 0276-603Cable Construction1- Solid or stranded, plain copper conductor- to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1 or cl. 2 and IEC 60228 cl. 1 or cl. 22- XLPE insulation type DIX3 acc. to VDE 0276-603/5G- Color coded to DIN VDE 0293(HD 308)- PVC filler4- Concentric conductor: Copper wires and copper tapes5- PVC outer jacket DMV5 to HD 603.1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 4000 volts- Minimum bending radius: 15 x Ø- Flexing temperature: -5º C to +70º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +250º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²CONDUCTORTYPETHICKNESS OF INSULATION MMTHICKNESS OF SHEATH MMCONCENTRICCONDUCTOR SIZE MM²NOMINALOVERALL DIAMETER MMCABLE WEIGHT KG / KM161x1.5re/rm0.71.81.59.7114141x2.5re/rm0.71.82.510.2135121x4re/rm0.71.8410.8170101x6re/rm0.71.8611.321481x10re/rm0.71.81012.430461x16re/rm0.71.81613.843141x25rm0.91.81615.554821x35rm0.91.81616.665011x50rm11.82518.88922/01x70rm1.11.83521.012073/01x95rm1.11.85023.516004/01x120rm1.21.87026.02045300mcm1x150rm1.41.87028.02320350mcm1x185rm1.61.89530.52942500mcm1x240rm1.71.912034.03761750mcm1x300rm1.82.115037.04591-1x400rm2218541.55830-1x500rm2.22.324046.07450-1x630rm2.42.530052.09561-1x800rm0.71.840058.012290162x1.5re/rm0.71.81.513.0198142x2.5re/rm0.71.82.513.9239122x4re/rm0.71.8415.0304102x6re/rm0.71.8616.238482x10rm0.71.81018.154662x16rm0.71.81621.076642x25rm0.91.81624.0103022x35rm0.91.81626.0128312x50rm11.92529.516312/02x70rm1.123533.022473/02x95rm1.12..25037.530284/02x120rm1.22.37042.03817300mcm2x150rm1.42.57046.04526350mcm2x185rm1.62.69551.05694500mcm2x240rm1.72.812057.07302750mcm2x300rm1.83.115063.09049163x1.5re/rm0.71.81.513.5218143x2.5re/rm0.71.82.514.5270123x4re/rm0.71.8415.7348103x6re/rm0.71.8616.944683x10rm0.71.81019.064563x16rm0.71.81622.091643x25rm0.91.81625.0126023x35rm0.91.81627.5159713x50sm11.92530.019192/03x70sm1.11.93534.026973/03x95sm1.125037.536084/03x120sm1.22.27041.54531300mcm3x150sm1.42.37046.55459350mcm3x185sm1.62.59551.06820500mcm3x240sm1.72.612057.58834750mcm3x300sm1.82.815062.510899164x1.5re/rm0.71.81.514.3250144x2.5re/rm0.71.82.515.4315124x4re/rm0.71.8416.8406104x6re/rm0.71.8618.152384x10rm0.71.81020.577264x16rm0.71.81623.5110044x25rm0.91.81627.5154124x35rm0.91.91630.0197614x50sm122533.524282/04x70sm1.12.13538.534183/04x95sm1.12.25042.545834/04x120sm1.22.47048.05807300mcm4x150sm1.42.57054.06992350mcm4x185sm1.62.79558.58704500mcm4x240sm1.72.812065.511283750mcm4x300sm1.8315071.513920165x1.5re/rm0.71.81.515.2291145x2.5re/rm0.71.82.516.4365125x4re/rm0.71.8417.9476105x6re/rm0.71.8619.561785x10rm0.71.81022.590965x16rm0.71.81625.5130045x25rm0.91.81629.5184425x35rm0.91.91632.5239015x50rm1.12.22537.03120
Other supplier products
|
|
NF M 87-202 EGSFAPPLICATIONThese NF M 87-202 EGSF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units par... |
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8304ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
S10 IYOI(c) 60 V NEK606 Armoured Tele cableApplications :These cables are flame retardant,Website:, low smoke and halogen free, used for indoor tel... |
|
|
Multipair Individually Screened Cables-Belden Equivalent 9775,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808ApplicationsThese cables are used as HV feeder cables in fixed conditions.StandardsAS/NZS... |
供应产品
Same products