450/750V SR Insulated Overall Screened Fire Resistant Control Cables (1-4 Cores Multicores)

450/750V SR Insulated & Overall Screened fire resistant Control Cables (1-4 Cores & Multicores)(PH30/60)(CU/SR/OS/LSZH 450/750V Class 5)Application:The cables are designed,Website:, manufactured and tested for general application in power and signal wiring, for emergency circuit and fire circuit control where high rejection to electrostatic noise is needed.STANDARDS:Basic design adapted from BS 7629-1FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)Circuit Integrity with mechanical shockEN 50200(PH30/60); CEI 20-36/4-0Circuit Integrity with mechanical shock & water sprayEN 50200 annex ESystem circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING450/750 VCABLE CONSTRUCTION Conductors: Plain annealed copper wire, flexible according to IEC(EN) 60228 class 5.Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.Cabling: The cores are cabled together in concentric layers with suitable non-hygroscopic fillers.Overall screen: Aluminum/polyester tape with tinned copper drain wire.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation Colour:Without earth conductor2 cores blue - brown3 cores brown - black - grey4 cores blue - brown - black - grey7 cores and above black numberedWith earth conductor3 cores yellow/green - blue - brown4 cores yellow/green - brown - black - grey5 cores yellow/green - blue - brown - black - grey7 cores and above yellow/green - black numberedSheath Colour: Colour red (other colours on request)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -30°C – +90°CTemperature range during installation (mobile state): -20°C – +50°CMinimum bending radius: 7.5 x Overall DiameterElectrical PROPERTIESDielectric test:2500 V r.m.s. x 5' (core/core)Insulation resistance≥300 MΩ x km (at 20°C)Short circuit temperature350°CCONSTRUCTION PARAMETERSCable CodeNo. of Core X Cross SectionNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox.Weightmm2mmmmmmkg/km2 coreSR (PH30/60)2x0.750.70.97,669SR (PH30/60)2x1.00.71.08,078SR (PH30/60)2x1.50.81.08,388SR (PH30/60)2x2.50.91.19,81233 coreSR (PH30/60)3x0.750.70.98,084SR (PH30/60)3x1.00.71.08,286SR (PH30/60)3x1.50.81.08,8112SR (PH30/60)3x2.50.91.110,41594 coreSR (PH30/60)4x0.750.71.08,7103SR (PH30/60)4x1.00.71.18,9110SR (PH30/60)4x1.50.81.19,8141SR (PH30/60)4x2.50.91.211,41967 coreSR (PH30/60)7x1.00.71.110,8176SR (PH30/60)7x1.50.81.211,7218SR (PH30/60)7x2.50.91.313,430512 coreSR (PH30/60)12x1.00.71.213,9275SR(PH30/60)12x1.50.81.315,3352SR (PH30/60)12x2.50.91.517,950519 coreSR (PH30/60)19x1.00.71.416,4408SR (PH30/60)19x1.50.81.518,2535SR (PH30/60)19x2.50.91.621,1760Electrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductorcross-sectionalareaReferenceMethod 4(enclosed in an conduitinsulated wall etc)Reference Method 3(enclosed in conduit on a wall or ceiling, or in trunking)Reference Method 1 (clipped direct)Reference Method 11(on a perforated cable tray), or Reference Methodone 3-corecable or one4-core cable3-phase a.c.one 2-core cable single phasea.c. or d.c.one 3-corecable or one 4-core cable 3-phase a.c.one 2-corecable singlephasea.c. or d.c.one 3-core cable or one 4-core cable3-phase a.c.one 2-corecable singlephasea.c. ord.c.one 3-core cable or one4-core cable3-phase a.c.12345678mm2AAAAAAA1.516.52219.5242226232.Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2-core cable d.c.2-core cable single- phase a.c3-core or 4-core cable 3-phase a.c.1234mm2mV/A/mmV/A/mmV/A/m1.53131272.


在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Type G Two-Conductor Flat Portable Power Cable 2kVApplicationsThese flat parallel cables are designed for use on D.C. off-track mining equipment,We...
NF M 87-202 EGPFAPPLICATIONThese NF M 87-202 EGPF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units par...
NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used as power supply or connection cables for large...
German Standard Industrial Cables LiYCY TPApplication and DescriptionLiYCY TP twisted cable is used for flexible use witd free movement,Website:, b...
Type 260 1.1 to 11KV AS/NZS 1802ApplicationsThese armoured cables are mainly used as feeder cables for power supply where mechanical protection and...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes