Type SHD-GC Three-Conductor Portable Power Cable, CPE Jacket 5kV ICEA S-75-381
Type SHD-GC Three-Conductor Portable Power Cable,Website:, CPE Jacket 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for applications such as longwall shearers, continuous miners and mobile equipment such as shovels, dredges and drills.StandardsICEA S-75-381/NEMA WC 58ASTM B 172ASTM B 33CAN/CSA C22.2 No. 96ConstructionConductorsStranded annealed tinned copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldTinned copper/textile braid.Ground Check ConductorTinned copper with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketReinforced extra-heavy-duty Chlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 6×ODMaximum Operating Temperature: +90℃Dimensions and Weight:
ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominal Jacket ThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×61331080.1102.80.1854.71.5639.×4259880.1102.80.1854.71.6842.×2259680.1102.80.2055.21.8747.×1259580.1102.80.2055.21.9549.×1/0266480.1102.80.2205.62.0852.×2/0329380.1102.80.2205.62.2055.×3/0418280.1102.80.2356.02.3659.×4/0532180.1102.80.2356.02.5063.×2506271/060.1203.00.2506.42.6968.×3007411/060.1203.00.2506.42.8171.×3508882/060.1203.00.2656.72.9574.×50012214/060.1203.00.2807.13.3184.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Other supplier products
|
|
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Single Triple)RE-2Y(St)HSWAH 70°C / 300 VSTANDARDSBasic d... |
|
|
300/500V XLPE Insulated LSZH sheathed Flame retardant Power Cables (single core) Application:The cables are mainly used in power stations,Website:,... |
|
|
0.6/1 kV Mica Tape + XLPE Insulated,Website:, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables (Multicore)ApplicationThese unarmoured fir... |
|
|
PE Insulated,Website:, LSZH Sheathed, CWB Screened Instrumentation Cables (Multipair)RE-2Y(C)H 90°C / 300VSTANDARDSBasic design to EN 50288-7APPLIC... |
|
|
Multipair Individually Screened Cables-Belden Equivalent 9775,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
供应产品
Same products