.

THHN/THWN, 600V, Type TC Control Cable

UL Industrial Cables THHN/THWN,Website:, 600V, Type TC control Cable Application and DescriptionType TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired. Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire. Type TC is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Conductors may be used at temperatures not to exceed 75°C in wet locations or 90°C in dry locations. 130°C for emergency overload ratings, and 250°C for short circuit ratings. Not recommended in D.C. operation in wet locations.Cable ConstructionConductorSoft annealed bare copper, Class B stranding per ASTM B8InsulationPolyvinyl chloride (PVC) insulation over witd a nylon (polyamide) jacket appliedAssemblyThree or more conductors will be cabled round witd fillers and a nylon rip cord is put under tde jacket for ease of strippingJacketHeat retardant, moisture and sunlight resistant PVCColorupon request, black is preferableTechnical Compliances- NFPA 70 (NEC)- UL 1581 - Electrical Wires, Cables and Flexible Cords- ICEA S-58-679 - Control Cable Conductor Identification Metdod 1, Table 2- UL 1685 - UL Flame Exposure Test (70,000 Btu/hr)Cable ParameterInsulation tdickness: 16-12AWG PVC 15mils(0.38mm) Nylon 4mils(0.10mm)10AWG PVC 20mils(0.50mm) Nylon 4mils(0.10mm)AWG 16 (26 STRANDS) - TYPE TC-TFFN* CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.2887.32436430.0451.140.3037.70537940.0451.140.3298.36669850.0451.140.3579.078112070.0451.140.3869.8010315390.0451.140.44711..0451.140.50112..0601.520.58514..0601.520.61415..0601.520.71318..0802.030.75319..0802.030.81220.62477709AWG 14 (7 strands) - Type TC-THHN or THWN ConductorsNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.3057.8568330.0451.140.3228.27411040.0451.140.3508.99313950.0451.140.3819.710916260.0451.140.41310.512919270.0451.140.41310.514521580.0451.140.44611.316424390.0451.140.47812.2182271100.0601.520.55014.0217322120.0601.520.56814.4251373150.0601.520.62715.9305454190.0601.520.65816.7373555200.0601.520.69117.6393584250.0601.520.76619.4483719300.0601.520.81020.6568845370.0802.030.91323.27201072AWG 12 (7 STRANDS) - TYPE TC-THHN OR THWN CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.3408.67511230.0451.140.3609.210515640.0451.140.39210.012819050.0451.140.42810.915422960.0451.140.46611.818327270.0451.140.46611.820730880.0451.140.50412.823434990.0601.520.57214.5277412100.0601.520.62115.8307457120.0601.520.64116.3358532150.0601.520.71018.0438652190.0601.520.74618.9539802200.0601.520.78519.9568845250.0802.030.91123..0802.030.96324..0802.031.03626.310441553AWG 10 (7 STRANDS) TYPE TC-THHN OR THWN CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.40710.311116630.0451.140.43311.015523040.0451.140.47312.019829450.0601.520.54913.925037160.0601.520.59615.129443770.0601.520.59615.133349580.0601.520.64516.437756190.0601.520.69317.6421626100.0601.520.75519.2467694120.0601.520.78019.8547814150.0802.030.90823..0802.030.95424..0802.031.00325..0802.031.11228..0802.031.17729..0802.031.27132.316142402


在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Fire resistant Central Loose Tube Fiber Optic cables FR200P 05M2XSH-R (CU/MICA+XLPE/OS/LSZH 300/500V Class 2 )Application:These cables are characte...
S12 RU(c) 250 V EPR insulation,Website:, SHF2 sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low smoke ...
UL Industrial Cables XHHW/XLPO,Website:, Type TC ControlApplication and DescriptionXHHW XLPO type TC Control Cable is for use in industrial power o...
S9 IYXI(c) 60 V Collective Shielding Tele Cable NEK606Applications :These cables are flame retardant,Website:, low smoke and halogen free, used for...
Three Core Medium Power Cable to VDE 0276Application:The three core cables are designed for distribution of electrical power with nominal voltage U...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes