Photovoltaic 1000 DC Power SPD

SPD for DC power, SPD1000VDC; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication;

Features & Advantages of Photovoltaic DCSPD1000

Status indication:

Green: OK

Red: Failed

DC power surge protector modules can be replaced online.

Remote alarm output is optional, named with "F".

It is normally installed at the boundary of LPZ1 and LPZ2 or subsequent LPZs.

Parameter of1000 DC Power PhotovoltaicSPD

T2-1000T2-1000F

1000VDC

Short-circuit current rating Iscpv

1000A

Nominal discharge current In(8/20µs)

20kA

40kA

Voltage protection level Up

4kV

Recommended backup fuse

80A gG

Recommended grounding cable

6~35mm2

Response time

25ns

Residual current IPE

<10μA

Remote alarm output

250VAC/0.5A;24VDC/0.5A

Housing protection grade(IEC60529)

IP 20

Housing material/inflammability rating(UL94)

PA66/V0

Testing standard

IEC 61643-31

CHENZHUstrives to provide high-quality products and services to meet the expectations of our customers and interested parties by delivering outstanding performance. We have special talents to research and develop safety and automation system. Indeed, automation and safety are our interface products' main characters.



在线联系供应商

至: Shanghai Chenzhu Instrument Co., Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

The Principle and Classification of Safety Barriers
The Principle and Classification of Safety Barriers China safety barrier is generally used in intrinsic safety systems. Intrinsic safety refers to system explosion-proof technology, which refers to t...
GS8500-EX Communication Input Intrinsic Safety Barrier
GS8500-EX Communication Input Intrinsic Safety Barrier Communication signals input isolated barriers, realize the bi-direction communication between hazardous area and safe area. It also provides an iso...
CZWB Series Temperature Transmitter
CZWB Series Temperature Transmitter The CZWB series is an intelligent digital temperature transmitterdesigned specifically for industrial complexity. Unlike the din rail mounted type,...
Photovoltaic 1000 DC Power SPD
Photovoltaic 1000 DC Power SPD SPD for DC power, 1000v spd; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features & Advantages of Photovoltai...
20KA AC Power SPD
20KA AC Power SPD SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 10kA/phase, Imax: 20kA/phase; hot-pluggable; fault indication. Features & Adv...
供应产品

Same products

Wiring Harness Connector
Wiring Harness Connector 卖方: Aupins Technology Co., Ltd Connector plugs are used as electromechanical components to connect electrical circuits. AP team ...
SAE J1772 Charging Connector
SAE J1772 Charging Connector 卖方: Aupins Technology Co., Ltd AP SAE J1772AC EV charging plug conforms to SAE J1772provisions and requirements. It is compatibl...
IEC 62196-2 Charging Connector
IEC 62196-2 Charging Connector 卖方: Aupins Technology Co., Ltd AP IEC AC charging plugs conform to IEC 62196-2 2-llb provisions and requirements. It is compatib...
Hyperboloid Contacts
Hyperboloid Contacts 卖方: Aupins Technology Co., Ltd The hyperboloid contactsspring terminal is the patented product specially developed and researche...
GB/T Charging Connector
GB/T Charging Connector 卖方: Aupins Technology Co., Ltd GB/T Charging Connector is widely used in the AC charging system of electric vehicles and conform...