Type 241 1.1 To 11KV To AS/NZS 1802
Type 241 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are designed for various uses,Website:, including main feeder cable for continuous miners, pump cable, and power supply cable. Overall semiconductive screen provides protective earth contact for any object breaching the sheath prior to contact with power conductors.StandardsAS/NZS 1802:2003AS/NZS 1125AS/NZS 3808AS/NZS 5000.1Construction3×ConductorsFlexible stranded tinned annealed copper conductor.Conductor ScreenSemiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).InsulationEPR.Insulation ScreenSemiconductive elastomer.Cradle SeparatorSemiconductive PCP.Overall Core ScreenSemiconductive PCP filling and covering.3×Interstitial Earth ConductorSemiconductive PCP covered flexible stranded tinned copper conductor.1×Central Extensible PilotEPR covered flexible stranded tinned copper conductor.Textile ReinforcementOpen-weave braid reinforcement.SheathHeavy duty PCP sheath.Heavy duty CPE/CSP sheath can be offered upon request.Dimensions and WeightNominal Conductor AreaStrandSizeInsulation ThicknessEarth ConductorPilot ConductorThickness of Sheath IncludingSC PCPLayerNominal Overall DiameterNominal WeightStrandSizeThickness of CoveringStrandSizeThickness of Coveringmm2No/mmmmNo/mmmmNo/mmmmmmmmkg/100mType 241.1684/0.301.518/0.301.024/0.200.83.828.51061077/0.401.527/0.301.024/0.200.83.831.112716126/0.401.642/0.301.024/0.200.83.934.116425209/0.401.666/0.301.024/0.200.84.237.920835285/0.401.690/0.301.024/0.200.84.441.225450380/0.401.7120/0.301.040/0.200.84.945.932870203/0.671.839/0.671.040/0.200.85.352.248095259/0.672.039/0.671.040/0.200.85.856.7600120336/0.672.142/0.671.240/0.200.86.362.7710150427/0.672.354/0.671.240/0.200.86.768.3865185518/0.672.563/0.671.440/0.200.87.374./0.672.877/0.671.440/0.200.88.083./0.673.098/0.671.440/0.200.88.791.21600Type 241.316126/0.403.042/0.301.024/0.200.85.043.824925209/0.403.066/0.301.024/0.200.85.347.731535285/0.403.090/0.301.024/0.200.85.651.137650380/0.403.0120/0.301.240/0.200.86.055.245070203/0.673.039/0.671.240/0.200.86.460.357695259/0.673.048/0.671.240/0.200.86.863.8675120336/0.673.060/0.671.240/0.200.87.269.1810150427/0.673.077/0.671.240/0.200.87.673.8952185518/0.673.091/0.671.440/0.200.88.079./0.673.0112/0.671.440/0.200.88.686./0.673.0144/0.671.440/0.200.89.192.61660Type 241.616126/0.405.042/0.301.424/0.200.86.154.936525209/0.405.066/0.301.424/0.200.86.458.844035285/0.405.090/0.301.424/0.200.86.762.250950380/0.405.0120/0.301.440/0.200.87.166.259270203/0.675.039/0.671.440/0.200.87.471.272795259/0.675.048/0.671.440/0.200.87.974.8835120336/0.675.060/0.671.440/0.200.88.380.2990150427/0.675.077/0.671.440/0.200.88.684./0.675.091/0.671.440/0.200.89.090./0.675.0119/0.671.440/0.200.89.696./0.675.0156/0.671.440/0.200.810.2103.61900Type 241.1125209/0.407.666/0.301.824/0.200.87.873.264535285/0.407.690/0.301.824/0.200.88.176.672450380/0.407.6120/0.301.840/0.200.88.580.682570203/0.677.639/0.671.840/0.200.88.985.797595259/0.677.648/0.671.840/0.200.89.389./0.677.660/0.671.840/0.200.89.794./0.677.677/0.671.840/0.200.810.098./0.677.691/0.671.840/0.200.810.4104.21610
Other supplier products
|
Fire Resistant Tight Buffered Distribution Fiber Optic Cables |
Fire Resistant Tight Buffered Distribution Fiber Optic cables Application:This cables are used for interconnection of distribution boxes and end de... |
|
150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Fire Resistant Instrumentation Control Cables |
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control CablesApplication:... |
|
450/750V SR Insulated LSZH Sheathed Control Cables (2-5 Cores) |
450/750V SR Insulated fire resistant control cables (2-5 cores)(PH60) (CU/SR/LSZH 450/750V Class 2)Application:The cables are designed,Website:, ma... |
|
600/1000V LSZH Sheathed, Overall Screened & Armoured (single Core) |
600/1000V LSZH Sheathed,Website:, Overall screened & Armoured (single core)Application:This range of screened cables drastically reduce interferenc... |
|
PE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Multicore) |
PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multicore)RE-2Y(St)H 90°C / 500VSTANDARDSBasic design to EN 50288-7... |
All supplier products
Same products
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |