H05V2V2-F/H05V2V2H2-F
VDE Industrial Cables H05V2V2-F/H05V2V2H2-F Application and DescriptionThese cables are suitable for domestic premises,Website:, kitchen, office for light service or light portable apparatuses. With their special insulation and sheatd compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperature (like lighting system apparatuses) without contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high temperature use, skin contact must be avoidedStandard and ApprovalHD 21.12; HD 308 S2, DIN VDE 0281 part 1, part 12, DIN VDE 0293 part 308, DIN VDE 0295CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), CENELEC HD 21.12 S1 /EN50265-2-1Cable Construction- Bare copper fine wire conductor- Stranded to DIN VDE 0295 cl. 5, IEC 60228 cl. 5 and HD 383- PVC core insulation T13 to VDE-0281 Part 1- Green-yellow grounding (3 conductors and above)- Color coded to VDE-0293-308- PVC outer jacket TM3Technical Characteristics- Working voltage: 300/500 volts- Test voltage: 2000 volts- Flexing bending radius: 15 x Ø- Static bending radius: 4 x Ø- Flexing temperature: +5º C to +90º C- Static temperature: -40º C to +90º C- Short circuit temperature: +160º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM²NOMINAL THICKNESS OF INSULATIONMMNOMINAL THICKNESS OF SHEATHMMNOMINAL OVERALL DIAMETERMMNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KMH05V2V2-F18(24/32)2 x 0.750.60.86.214.454.218(24/32)3 x 0.750.60.86.621.66518(24/32)4 x 0.750.60.87.12977.718(24/32)5 x 0.750.60.983697.317(32/32)2 x 1.000.60.86.41960.517(32/32)3 x 1.000.60.86.82973.117(32/32)4 x 1.000.60.97.6389317(32/32)5 x 1.000.60.98.348111.716(30/30)2 x 1.500.70.87.42982.316(30/30)3 x 1.500.70.98.143104.416(30/30)4 x 1.500.71.0958131.716(30/30)5 x 1.500.71.11072163.114(30/50)2 x 2.500.81.09.248129.114(30/50)3 x 2.500.81./50)4 x 2.500.81.110.996199.614(30/50)5 x 2.500.81.212.4120245.412(56/28)3 x 4.000.81.211./28)4 x 4.000.81.212./28)5 x 4.000.81.413./28)3 x 6.000.81.113./28)4 x 6.000.81.313.9230490H05V2V2H2-F18(24/32)2 x 0.750.60.84.2 x 6.814.14817(32/32)2 x 1.000.60.84.4 x 7.21957
Other supplier products
|
|
450/750V SR Insulated & Overall Screened fire resistant Control Cables (1-4 Cores & Multicores)(PH30/60)(CU/SR/OS/LSZH 450/750V Class 5)Application... |
|
|
Flame Retardant CAT5e Data CablesCAT5e U/UTP4P24CAT5e F/UTP4P24CAT5e SF/UTP4P24Application:Cat5E is a cable standard for Gigabit Ethernet and other... |
|
|
Multipair Individually Screened Cables-Belden Equivalent 9775,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
3.6/6KV,Website:, 6/10KV, 8.7/15KV, (FA-)SPYC, SPYCB, TPYC (FA-)SPYCY, SPYCBY, TPYCYStandards:JISC 3410-1999
IEC 60092-350
IEC 60092-35... |
|
|
UL Industrial Cables RHH or RHW-2 or USE-2,Website:, 600V, EPR / CSPApplication and DescriptionThese cables are designed for use in lighting and po... |
供应产品
Same products